21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer

Product Details
Customization: Available
Certification: CE, ISO, CE, ISO, CE
Customized: Customized
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2007

Suppliers with verified business licenses

Type of Ownership
Limited Company
Plant Area
>2000 square meters
  • 21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
  • 21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
  • 21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
  • 21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
  • 21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
Find Similar Products

Basic Info.

Model NO.
21 MVA MVA 33/0.48- 0.192 KV
Surface Treatment
Painted
Fuel
Gas Coal Electric, Electric
Range of Applications
Industrial, Industrial
Type
Cusomized, Eaf
Place Style
Vertical
Usage
Steel Molding
Transport Package
Nude, Wooden Cases
Specification
As per drawing
Trademark
Ville Industry
Origin
China
HS Code
851300020
Production Capacity
300units Per Year

Product Description

21mva electric arc furnace with serial reactor
The tansformer rating is 21 MVA'33000/ 480 - 372-192 Volt, 3 phase, 50 Hz suitabIe for furnace duty appliCation. lt is povided with coolers for OFWF (Oil forced  water forced) Cooling. The salient featues of the Transformer are as foIIows: 
The tansformer Rating No-1oad voitage HV V Tap cha=gjng equipment Frequency Type of coo=ng Connections CooIer capacity OIow ate Wate fiow rate Curent Transfome Customer STEEL, HAMA, 21 MVAfo LV480 to 372 voIts 21 MVAto lO.84 MVAfoLV372 to 192 volts 33000 voIts 480 to 372 V (Constant MVA) Taps at constant MVA: 480'462,444,426, 408,390,372 372 to 192 V (Constant curent) Taps at constant current‥ 372354,336,318,300, 282,264)246,228,210,192 Taps ae povided on HV side to vary LV as mentio=ed above by means of on-Ioad tap change Suitable fo local manua,ocaI eIectical and emote eIecticai opeation. Type-M350Y72.51B, 10.19.3W Make - Eason MR 50Hz OFWF 2X lOO% HV- DeIta LV- Open DeIta 350 KW(1 Running + 1 standby) 1190 PM C○○Ie. WTI CT: 367.41 1.7,18,2.0 7.5VA, CIassO.5 On HVside
1.1 TECHNICAL DESCRIPTION   (Solution 1: MR VMIII 650/72D OLTC,with booster transformer )
1.1.1 GENERAL TECHNICAL DATA  
Highest voltage 36kV 50Hz
Operating voltage 33 kV±5% 50Hz
Voltage for aux. drivers 380V 50Hz
Control voltage 220V 50Hz
Interlock voltage 220V 50Hz
PLC signals 24V DC
Ambient temperature max./min. 45 / - 10 Deg. C
Altitude 1500 m
Humidity 80 %
1.1.2 TRANSFORMER DATA   
Operating voltage   33kV±5%
Frequency    50Hz  ±1%
Operation     Continuously
Rated capacity     25 MVA + 20% Overload
Rated primary current      437.4 A    (+ 20% Overload)
Insulation level
Winding:
Um:
AC:
BIL:

MV         LV
52 kV       1,1 kV
95 kV       6  kV
250 kV       - 
Protection level        IP54
Vector group          D/d0  
Secondary connection   Open Delta  
System short circuit capacity    1500 MVA
Secondary current      35.042 KA   (+ 20% Overload)
Secondary voltage range    480 -412--208 V   (480 V at tap position 1)
 (See APPENDIX: Data for reference )
Constant power  480412 
Constant current        412-208  V
Regulation method  Constant flux, Tapping with booster transformer 
Short-circuit impedance voltage        7.1 %   (at LV max. Voltage 480V)
8.69  %   (at LV 412 V)
 
Short circuit duration 3 sec
Type of tap changer           On-load , Oil Immersed Type
Manufacturer             HM China  (Shanghai Huaming)
Model       M III-600 /72B-10193W
Number of taps 17
Winding Materials Copper
Cooling Type OFWF   
a.  Number of heat exchanger  ( 1 work 1 standby )  
b. Capacity of each heat exchanger     100%
c.  Heat Duty 400 kW  (each cooler) 
d. Volume of  flow water side/oil side 3065  m3/h  (each cooler)
e.  Water inlet temperature (max.)   35 ºC
f.   Water outlet temperature 45 ºC
Tank  Conventional Type (Drum type for OLTC)
Temperature rise limitation           
Top oil temperature        45 K (85°C)
Winding temperature   50 K (90°C)
Core and metal parts 60 K (100°C)
Product executed standard o IEC 60076IEC 60076 POWER TRANSFORMERS
o IEC 60354 LOADING GUIDE FOR OIL IMMERSED POWER TRANSFORMERS
o IEC 60214 TAP CHANGER
o IEC 60044 CURRENT TRANSFORMER
o IEC 60060 HIGH VOLTAGE TEST
o IEC 60137 BUSHING
o IEC 60270 PD MEASUREMENT
o IEC 60412-60296-60599 MINERAL INSULATION OIL
o IEC 60507 ARTIFICIAL POLLUTION TEST
o IEC 60616 TERMINAL AND TAPPING MARKING
o IEC 60551 DETERMINATION OF TRANSFORMER SOUND LEVEL.
o IEC 60551 RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS
Reference standard       Arc furnace transformer standard JB/T 9640-2014
No load losses  (At LV Max. Voltage)         80 kW ( for core plate 27Q120 ) (Confirmed)
  58 kW ( for core plate 27RK85)
Load losses at 75ºC
 (Tap 1 , 480 V, 25 MVA)    
                170 kW  
Active part weight      34 600 kg   
Copper weight 71 000 kg   
Oil weight            14 600 kg     
Transport weight      56 500 kg    (with oil) 
43 500 kg    (without oil) 
Total weight           63 000 kg     
Dimensions          L×W×H    See Outline Dimensions and Assembly Drawing in detailed
HV Bushings and LV Terminals            HV side: 3 porcelain bushings:
 46kV/3150A BIL 250kV AC 95                                           LV side: 
Copper bus Plates on top of the tank, AC kV
Conductor type of wiring     Continuously transposed conductor or copper flat
1.1.3 Cooling system
 
Double wall type cooler should have their individual circulation pump, and also coolers will be 1  in service the other 1 for stand-by  
2 coolers  (3x70%
2 oil circulation pumps     
1 oil flow indicator for each cooler with two electric contact (1 alarm - 1 trip)
1 water flow indicator for each cooler with two electric contact (1 alarm - 1 trip)  
2 Pressure gauges on each cooler 1 for oil 1 for water
2 Thermometers for each cooler 1 for oil 1 for water
Leakage detector with contacts 1 piece for each cooler
1.1.4 On - load tap changer


 
Manufacturer:  HM CHINA 
(SHANGHAI HUAMING, CHINA FAMOUS BRAND)
Model: CMIII-600/72B-10193W , Oil immersed type OLTC with pressure relief valve. Oil filter should be applied. 
Nominal current : 600 A
Um :72 .5kV
17 Taps controlled by motor drive unit locally and remotely from the pulpit room, also operations by crank are possible for emergency purpose. Motor or hand operations are interlocked, So it is not possible to operate by hand and by motor at the same time. Selector switch for local and remote control with auxiliary contact. In the control box, two sets of contacts are provided for signaling the Tap Changer Positions and for controlling the electrodes. The detailed requirement is as following: 
N°1 On-Load Tap-Changer with electrical local panel for local/remote control complete with push buttons/selectors/relay and interface terminal blocks. Hand operation by crank has to be possible for emergency purpose. The following signals shall be provided but not limited. N°1 contact for "OLTC ready (when ready CLOSE)"; N°1 contact for "OLTC running (when running OPEN)"; N°1 contact for "OLTC not in position (when not in position OPEN)"; N°1 contact for "OLTC MOTOR - RUNNING FW (when running FW CLOSE); N°1 contact for "OLTC MOTOR - RUNNING BW (when running BW CLOSE). The control board shall include n°3 terminal strips for remote signaling of the transformer tap position: two of these terminal strips must be BCD type and the other one "break before make" type; 
1.1.5 Monitoring and Protection Device


 
1 Buchholz relay with 1NO contacts for alarm and 2 NC contacts for trip
2 oil level indicators for two conservator-sections:
 1 electric contact provides an alarm signal for the minimum admissible oil level for each section.
1 Top oil thermometer indicator with 2 NC contacts for TRIP and 2 NC contacts for ALARM.
1 Winding thermometer indicator with 2 NC contacts for TRIP and 2 NC contacts for ALARM
1 over-pressure relief device for main tank, Each will be with 2 contacts :one for alarm and the other for trip 
1 protective relay for OLTC with 2 contacts for TRIP
Differential pressure switch for each oil-water heat exchanger to detect water leakage ALARM
1 PT-100 for oil temperature indication of main tank
1 Circuit breaker cooling pump for each pump
1 Signal cooling pump running for each cooler
1 Signal cooling pump failure for each cooler 
1 Circuit breaker for OLTC   
1 Signal OLTC running   
1 Signal OLTC failure    
Tap changer in progress signalization
1 Circuit breaker for OLTC Oil Filter
(to be kept)
1.1.6  Current transformer for electrode control
 
Matching Current transformers inside the tank 3 pcs. 439/2.88 A  50 VA for metering and for LV current control, for LV equivalent ratio of  50000/√3 //5/√3A. They located on the line of tap winding for series transformer primary winding. The current ratio must be comply with 20% overload.
Current transformer 1 pcs. 800./5 A 50 VA Class 1 for winding temperature on primary winding B phase.   
1.1.7 Control box (Auxiliary Cabinet)    1 control box containing electrical components for control of the cooling pump and for installation of the matching transformer for the secondary current measurement.
1 control box containing electrical components for the OLTC motor drive and oil filter.
1 control box containing electrical components for signals terminal of the other protective devices.( Merged in cooler control panel)
1.1.8 Valves   various valves  
1.1.9 Wheels  4 set flange wheels with bidirectional 
1.1.10 Oil conservator   Double chamber construction for transformer and OLTC.
1.1.11 Painting and Color  Painting thickness is 120-160um; Color RAL 7033
1.1.12 Noise Level 80 dB(A)
2. All accessories on the transformer
 
All the other accessories in the followings  will be added to transformer
2 Silica-gel breather
 (for the two conservator sections)
2 valves for removal of the conservator filled with oil
1 set of oil drain filtering and sample valves
4 lifting lugs for core & coils
4 lifting lugs for the complete transformer
1 rating plate
2 grounding terminals for tank
3. Testing  

 
Routine test according to IEC standards are included as flowing:
Appearance Check
Voltage Ratio Test
Winding Connection Group Measurement 
Winding DC Resistance Measurement
Insulation performance measurement, including insulation resistance, absorption ratio and medium consumption angle tangent value are required.
Transformer Oil Test
Induced Voltage Test
Applied Voltage Withstand Test and Impulse Test 
No-load Test
Short-circuit Test
Tank Oil Leakage Test
Core Insulation Resistance
Noise Level Test
Frequency Response Test
Remark    1.)Tank, Conservator and Cooler is vacuum proof
2.) Gaskets between cooler flange and transformer flanges should be supplied.
3) The RC and arrestor in primary must be installed by user; and C filter unit and fuse with support in secondary side should be installed, but the buyer pays the charges in additionally.

21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer

21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer

21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer

21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer
21 Mva Mva 33/0.48-0.192 Kv Furnace Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier