Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall

Product Details
Customization: Available
Certification: CE, ISO
Customized: Customized
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2007

Suppliers with verified business licenses

Type of Ownership
Limited Company
Plant Area
>2000 square meters
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
  • Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
Find Similar Products

Basic Info.

Surface Treatment
Painted
Fuel
Gas Coal Electric
Range of Applications
Industrial
Type
Cusomized
Place Style
Vertical
Usage
Steel Molding
Transport Package
Nude, Wooden Cases
Specification
As per drawing
Trademark
Ville Industry
Origin
China
HS Code
851300020
Production Capacity
30units Per Year

Product Description

Electric Arc Furnace Covers/Walls: Cooling flue is an important equipment for steelmaking in converter, which has the function of collecting, cooling and conveying flue gas, in addition, the flue is also a waste heat boiler for producing steam.Water-cooled furnace cover, including a large furnace cover and a small furnace cover, the small furnace cover is opened with electrode holes, the small furnace cover is arranged in the center of the large furnace cover, characterized in that: including a protective sleeve, set between the large furnace cover and the small furnace cover, the protective circumference of the wall of the water-cooled circulating pipe, the water-cooled circulating tube is connected to the ends of the water-cooled circulating pipe corresponding to the water inlet pipe, the water return pipe; set in the inner circle of the large furnace cover, and fixed with the large furnace cover, the small furnace cover is set in the protective sleeve Inner ring. Refining furnace water-cooled cover, the water-cooled structure in the cover consists of a number of seamless tubes arranged in close proximity. Each tube is circular in shape. The water-cooled refining furnace cover of this structure is not easy to leak and is easy to maintain.
The main technical solution of the cooling flue is to install cooling fins on the outer wall of the pipe, to connect an outer casing with an outer duct, to connect an axial fan using an air duct at one end of the outer casing, and to install an exhaust port at the other end of the outer casing. Said duct is connected to the outer casing in an inclined shape and the outlet of the duct faces the end of the outer casing on which the exhaust port is installed. A nozzle assembly is connected to the outer casing, the nozzle in the nozzle assembly facing the cavity between the outer casing and the pipe, and the nozzle assembly is connected to the water supply pipe using a receiver.
Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall
Features
Electric arc furnace cover is made of refractory bricks;
It has a certain ability to resist internal and external pressure and withstand high temperature;
Reinforced sealing design to prevent boiling overflow;
The structure design of water-cooled slag hanging in the triangular area improves the bearing capacity
of high temperature radiation and impact, and improves the overall service life of the furnace cover;
 
Products Description
Induction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling WallInduction Furnacewater-Cooled Tubular Cover Metal Mineral Smelting Cover Electric Arc Furnace Water Cooling Covers Water Cooling Wall

Description

Electric arc furnace cover, that is the steelmaking furnace cover, is composed of a water-cooled
cover (or a refractory brick cover), an electrode sealing ring, a feeding water ring and a water-cooled reinforcement ring.
 

Design, Manufacture And Furnace Cover Precautions For Use

1: The position design of electrode process holes, feeding process holes and dust removal process holes should be reasonable;
2: The furnace cover should have a certain ability to withstand high temperature, operating vibration
and internal and external pressure;
3: Pay attention to the sealing of each process hole and the interface with the furnace shell.

Electric Arc Furnace Cover Mainly Process Parameters

D is the diameter of the furnace cover;
Φ is the diameter of the electrode center circle;
d is the electrode hole diameter;
h is the arch height of the furnace cover.

Specification
Model
Furnace enclosure inner diameter
(mm)
Rate capacity/Max capacity (ton)
Furnace transformer
Reactor power
(KVA)
Electrode pitch circle diameter 
Electrode diameter(mm)
Rated power
(KVA)
Secondary voltage
(V)
 
HX-0.5
2000
0.5/1
630
200-98
120
500
150
HX-1.5
2200
1.5/3
1250
210-104
200
650
200
HX-3
2600
3/8
2200
210-104
250
750
250
HX-5
3200
5/12
3200
221-110
320
850
300
HX-10
3500
10/16
5000
240-121
360
1000
350
6300
260-139
360
HX-15
3700
15/20
6300
260-139
340
1000
350
9000
260-139
HX-20
4000/
4200
20/32
9000
260-139
/
1000
350
12500
340-195
/
1050
400
16000
375-200
/
1050
400
HX-30
4600
30/45
16000
375-200
/
1100
450
25000
570-350
4000
1100
450
32000
650-350
6800
1100
450
HX-50
5000
50/60
25000
570-350
4000
1100
450
32000
650-350
6800
1100
450
35000
670-370
7800
1100
450
HX-80
5800
85/95
35000
650-350
6800
1100
450
40000
690-390
8500
1250
500
50000
800-500
9800
1300
500
HX-100
6200
100/120
35000
670-520-370
7800
1100
450
50000
800-650-340
9800
1300
500
63000
920-720-480
13000
1350
600